Complete Fresh Air,
Ventilation & IAQ Systems
InAir offers a complete range of fresh air ventilation systems, energy recovery ventilators, heat pump air handling units, IAQ sensors, inline fans, exhaust fans, centrifugal fans, jet fans, filtration systems, ducting, dampers, and accessories.
From compact residential apartments to premium villas, schools, hospitals, offices, hotels, basements, commercial buildings, and industrial facilities — every InAir product is selected based on airflow requirement, application, and air quality outcome.

Share your floor plan, occupancy, application, and air quality target. Our design team will recommend the right product combination — at no charge.
On this page — 17 product families
InAir Revita & Ventura
Energy Recovery Ventilation Units
Revita (compact residential) and Ventura (large commercial) — InAir's ERV workhorses — continuously bring filtered outdoor air into indoor spaces while exhausting stale indoor air, recovering 80–90% of the thermal energy in the outgoing air stream. The result is continuously fresh, filtered, energy-efficient indoor air without burdening your AC system. The Revita handles every home project from 1 BHK to large villas; the Ventura handles offices, schools, and commercial buildings at scale.
Suitable for residences, villas, offices, schools, clinics, commercial spaces, hospitality projects, and institutional campuses.

| Model | Airflow | Heat Exchanger | Filtration | Power Supply | Construction | Ideal For |
|---|---|---|---|---|---|---|
| Revita INA-MFQR-150 | 150 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard compact | 1 BHK · Studio |
| Revita INA-MFQR-250 | 250 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard compact | 2 BHK Apartment |
| Revita INA-MFQR-350 | 350 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard compact | 3 BHK Apartment |
| Revita INA-MFQR-500 | 500 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard compact | 4 BHK / Villa |
| Ventura INA-QRXF-800 | 800 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard | Large Villa / Office |
| Ventura INA-QRXF-1000 | 1,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard | Office / School Zone |
| Ventura INA-QRXF-1300 | 1,300 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard | Large Office / School |
| Ventura INA-QRXF-1500 | 1,500 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | Standard | Commercial Building |
| Ventura INA-QRXF-2000-FS | 2,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | PUFF panel + Al frame | Large Bungalow / School Block |
| Ventura INA-QRXF-2500-FS | 2,500 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 220V / 50Hz / 1-Ph | PUFF panel + Al frame | Commercial / Institutional |
| Ventura INA-QRXF-3000-FS | 3,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 440V / 50Hz / 3-Ph | PUFF panel + Al frame | Institutional Building |
| Ventura INA-QRXF-4000-FS | 4,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 440V / 50Hz / 3-Ph | PUFF panel + Al frame | Large Commercial |
| Ventura INA-QRXF-5000-FS | 5,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 440V / 50Hz / 3-Ph | PUFF panel + Al frame | Hospital / Campus Block |
| Ventura INA-QRXF-6000-FS | 6,000 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 440V / 50Hz / 3-Ph | PUFF panel + Al frame | Large Campus |
| Ventura INA-QRXF-7500-FS | 7,500 m³/h | Plate-type (80–90%) | MERV-13 / HEPA-13 (grade by city) | 440V / 50Hz / 3-Ph | PUFF panel + Al frame | Industrial / Campus |
Filter requirements differ by location. Delhi winters need HEPA-13. Hyderabad and Bangalore may need different grades. Coastal cities have humidity considerations. Tell us your city — our engineer will recommend the right filter grade.
What size ERV do I need for a 3 BHK apartment in India?
What is 80–90% heat recovery and why does it matter?
What is the difference between MERV-13 / HEPA-13 filtration and a standard filter?
Can I install an ERV during renovation if my home is already built?
InAir RHP — Heat Pump Energy
Recovery Air Handling Units
InAir RHP units combine fresh air treatment, heat recovery, active cooling, heating, dehumidification, and MERV-13 / HEPA-13 filtration into one integrated air handling platform — built around an R410A refrigerant cooling coil that actively conditions incoming air to a precise 22–28°C. These units are ideal for projects where fresh air needs to be delivered at controlled temperature and humidity — regardless of outdoor conditions.

The direct expansion heat recovery system works with the plate-type heat exchanger to maximise energy recovery from exhaust air, improve system efficiency, and deliver treated fresh air with active cooling and heating capability.
| Model | Airflow | Cooling | Heating | Refrigerant | Power |
|---|---|---|---|---|---|
| RHP INA-RHP-006B1-C | 600 m³/h | 5.2 kW | 5.4 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-010B1-C | 1,000 m³/h | 8.3 kW | 9.1 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-020B1-C | 2,000 m³/h | 17.3 kW | 17.9 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-030B1-C | 3,000 m³/h | 25.6 kW | 26.8 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-040B1-C | 4,000 m³/h | 36.5 kW | 37.8 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-050B1-C | 5,000 m³/h | 44.5 kW | 46.0 kW | R410A | 380V / 3PH / 50Hz |
| Model | Airflow | Cooling | Heating | Refrigerant | Power |
|---|---|---|---|---|---|
| RHP INA-RHP-030A1-FS | 3,000 m³/h | 25.6 kW | 26.8 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-040A1-FS | 4,000 m³/h | 36.5 kW | 37.8 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-050A1-FS | 5,000 m³/h | 44.5 kW | 46.0 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-060A1-FS | 6,000 m³/h | 54.8 kW | 56.5 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-070A1-FS | 7,000 m³/h | 65.0 kW | 67.5 kW | R410A | 380V / 3PH / 50Hz |
| RHP INA-RHP-080A1-FS | 8,000 m³/h | 73.0 kW | 76.5 kW | R410A | 380V / 3PH / 50Hz |
What is the difference between an ERV and a Heat Pump ERV?
Does the Heat Pump ERV replace my AC system?
Does the Heat Pump ERV require three-phase power?
IAQ Sensors &
Smart Ventilation Controls
Traditional ventilation systems work on assumptions. InAir smart IAQ systems work on real-time data. By monitoring air quality parameters continuously, the ventilation system can respond to occupancy, pollutant load, humidity, and CO₂ levels — delivering fresh air when and where it is needed, and reducing energy when it is not.

| PM2.5 Monitoring | Real-time · laser particle counting |
| Temperature | Real-time monitoring |
| Humidity | Real-time monitoring |
| VOC Sensing | Standard VOC sensor |
| Connectivity | Standard WiFi |
| App Support | Android & iOS |
| Temperature Control | 22°C – 28°C precise regulation |
| PM2.5 Monitoring | Real-time |
| Temperature & Humidity | Real-time monitoring |
| VOC Sensing | Standard VOC sensor |
| Connectivity | Standard WiFi |
| Required For | All Heat Pump ERV units |
InAir IAQ sensors can be integrated with motorised dampers and BMS systems to enable classroom-level, room-level, or zone-level demand-controlled ventilation — as demonstrated in the Bloomingdale International School deployment.
What is demand-controlled ventilation and how does it work?
Which sensor is required for Heat Pump ERV units?
Standalone Fresh Air
Ventilation Units
Standalone InAir units are designed for spaces where full ducted ventilation may not be practical — finished homes, single-room applications, retrofit projects, and spaces where running ducting through a false ceiling is not feasible. They provide targeted fresh air ventilation with minimal installation complexity.

Inair works best during construction — but standalone and compact wall-mount units are available for finished homes. Our engineers will advise the most practical option for your specific space during a free site survey.
Talk to an engineer about your finished homeInline, Duct &
Silent Ventilation Fans
InAir inline and duct fans are compact, efficient air movement solutions for ducted ventilation, exhaust, air transfer, booster airflow, and silent indoor ventilation. The range includes purified duct fans, two-way ventilation duct fans, and inline air conditioner fans — each suited to specific duct layouts, airflow requirements, and installation conditions.

Model airflows: 120–920 m³/h. Noise: 21–45 dB. Static pressure up to 382 Pa. Contact us for model-specific technical datasheets and selection support.
Toilet Exhaust &
Odour Control Fans
InAir toilet exhaust systems are designed to remove odours, humidity, stale air, and pollutants from toilets, restrooms, cloakrooms, washrooms, service areas, and utility zones. The range covers compact residential exhaust fans to large ducted commercial exhaust systems — including silent, ultra-thin, EC smart, and high-capacity options.

Range includes mixed flow fans, direct duct fans, ultra-thin silent fans, EC inline duct fans with smart digital controllers, and kitchen/utility exhaust fans. Request datasheet for specific model specifications.
EC Inline Duct Fans
InAir EC Inline Duct Fans are designed for energy-efficient, low-noise, speed-controlled ventilation. EC (Electronically Commutated) motors provide superior controllability, longer service life, higher efficiency, quieter performance, and lower vibration compared to conventional AC motor fan systems — making them ideal for smart, BMS-integrated, and demand-controlled ventilation applications.

EC fan performance data and model specifications available on request. PWM control compatibility, BMS integration, speed range, and noise levels vary by model. Contact our team for selection support.
Mixed Flow, Direct Duct
& Circular Duct Fans
InAir offers multiple compact fan formats for different duct layouts, airflow requirements, and installation conditions. Mixed flow fans deliver strong airflow in ducted systems, direct duct fans are suited for short straight runs and direct wall exhaust, and circular duct fans integrate into round duct systems for kitchens, bathrooms, and utility spaces.

Airflow and pressure specifications vary by sub-type and model. Request full technical datasheet including mixed flow, direct duct, and circular duct model ranges.
Cabinet Type Forward
Centrifugal Fans
InAir Cabinet Type Forward Centrifugal Fans are designed for high-volume, low-noise commercial and industrial ventilation. The INA series forward-curved multi-blade design delivers high airflow at low noise levels, making these fans suitable for office buildings, hotels, theatres, auditoriums, basements, shopping malls, hospitals, and factories.

INA series: 13 models (250–1000), airflows 1,700–120,000 m³/h, total pressure up to 1,300 Pa. Belt drive, A/C/D transmission options. Request full technical datasheet and selection support for your project.
INA73 Industrial Radial
Centrifugal Fans
The InAir INA73 Industrial Radial Centrifugal Fan series is engineered for industrial air movement, air treatment, atmospheric control, environmental purification, and high-static-pressure ventilation applications. Available in Type A, C, and D transmission configurations with custom outlet angle and rotation direction options.

INA73 industrial fan range — specifications include multiple transmission types (A, C, D), custom outlet angles, and rotation direction options. Full technical datasheet, dimensional drawings, and selection support available on request.
Jet Fans for Basements,
Tunnels & Parking Ventilation
InAir Jet Fans are designed for thrust-based ventilation in basements, car parks, tunnels, and large enclosed spaces where ductless air movement, pollutant dilution, and smoke movement support are required. One-way and reversible models are available — reversible models switch between forward and reverse operation within 30 seconds.

Jet fan models from 6.3 to 12.5 — dimensional data, blade layout, thrust output, and mounting specifications available in full technical datasheet. Reversible models confirmed to rated speed within 30 seconds. Contact us for basement ventilation design support.
HEPA, Activated Carbon
& Filter Boxes
InAir filter boxes improve the quality of incoming or circulated air by combining pre-filtration, HEPA H13 filtration, and activated carbon filtration. Three-stage multi-layer filtration removes particles above 5 microns, fine PM2.5 and smoke, and gaseous pollutants including formaldehyde, odours, and VOCs. Filter boxes can be added to fresh air systems, ducted ventilation layouts, or standalone applications.

Filter box range: INAGLX-100, INAGLX-150, INAGLX-200, INAGLX-250. HEPA H13 grade across all models. Airflow range: 120–2600 m³/h. Duct sizes Φ100–Φ240mm. 15–25% airflow reduction to be factored in design.
Ducting, Dampers
& Airflow Control
Correct air distribution is as important as the ventilation machine itself. InAir offers a complete range of flat ducts, circular ducts, flexible ducts, dampers, non-return valves, motorised actuators, and airflow control components to ensure balanced, efficient, and correctly pressured air distribution through your ventilation system.

Flat duct system: 132×30mm ABS. Distribution boxes: 10-way and 12-way. Round duct connections: Φ75–Φ200mm. Flexible ducts: Φ80–Φ315mm. Control valves and check valves across Φ75–Φ200mm. Full accessories catalogue available to download.
Air Distribution
Accessories
InAir air distribution accessories complete the ventilation system by delivering air quietly, evenly, and aesthetically into occupied spaces. The range includes ceiling vent diffusers, external wall air vents, stainless steel sleek panels, air vent cowls, lintels, and connection boxes — engineered to deliver conditioned air without draught, noise, or visible ductwork.

Full accessories catalogue with part numbers, dimensions, and installation specifications available for download. Diffusers available in multiple designs for different ceiling types and aesthetic requirements.
Fresh Air Dehumidifier
with Rotary Heat Recovery
The InAir Fresh Air Dehumidifier with Rotary Heat Recovery brings fresh outdoor air indoors while reducing humidity and recovering energy from exhaust air. It filters outdoor air through G4 and H10 filters, exchanges sensible and latent heat through a total heat recovery wheel, dehumidifies through an evaporator and reheats air through a condenser before supply.
Filter grade depends on local AQI and application. Ask our engineer — tell us your city and building type.
What is the advantage of rotary heat recovery in the InAir fresh air dehumidifier?
Does the InAir fresh air dehumidifier filter incoming air?
Where can the InAir fresh air dehumidifier be installed?
Fresh Air Dehumidifier
Water Coil Series
The InAir Water Coil Fresh Air Dehumidifier uses filtration, plate heat exchange and water cooling coil treatment. Outdoor fresh air or mixed return/fresh air is filtered, pre-cooled through a plate heat exchanger, dehumidified through a water coil and passed again through the exchanger for sensible heat recovery.
Filter grade depends on local AQI and application. Ask our engineer — tell us your city and building type.
What is the difference between the INAD-CW30 and the INAD-CW50?
Does the INAD-CW series require chilled water?
Can the InAir fresh air dehumidifier be used as a standalone dehumidifier?
What is the difference between the Revita and Ventura ranges?
What does CMH mean and how is my home sized?
When do I need an RHP heat pump unit rather than a standard ERV?
How do I maintain the system, and how often do filters change?
If dust collects in the ceiling ducting, will the ceiling have to be opened?
Kitchen Exhaust &
Commercial Extraction Systems
InAir kitchen and commercial extraction systems are designed for removing heat, smoke, grease-laden air, odours, and contaminated exhaust from kitchens, restaurants, hospitality spaces, and utility areas. The range supports high-volume extraction with appropriate static pressure to overcome grease filters, duct bends, and long runs — critical for commercial kitchen performance.

Kitchen extraction system specifications depend on kitchen size, cooking load, grease filter type, duct length, and required extraction rate. Contact our team with kitchen dimensions and equipment list for a tailored recommendation.
Not Sure Which Product Fits Your Project?
Ventilation equipment should not be selected only by room size or machine capacity. The right system depends on airflow requirement, occupancy, filtration level, static pressure, duct routing, noise expectations, and IAQ targets. Share your floor plan and project details — our engineers will help you select the right combination.
What does it cost to buy, run and maintain?
What does a fresh air ventilation system cost in India?
Is a fresh air system expensive to run?
What is the payback period on an ERV?
How often do the filters need changing?
What maintenance does the system need?
Can I maintain it myself, or does it need a technician?
What happens if the unit is not maintained?
Does the warranty depend on servicing?
Is a cheaper exhaust fan not enough?
How much does running HEPA-13 add over MERV-13?
Further reading
- InAir Ventilation Systems India: Complete Range, Applications and Why It Matters
- Demand-Controlled Ventilation in India: CO₂ Sensors, IoT and Smart Building IAQ
- Why Fresh Air Ventilation is Now Non-Negotiable in India: The Case for ERV Systems
- Smart Home Ventilation in India: IoT, CO₂ Control and Automated Indoor Air Quality